Features & Benefits:
· Viscosys LLC offers a convenient solution to maintaining a wide range of
superpave equipment. We provide calibration / validation programs that meet
or exceed the requirements of AASHTO/AMRL. Instruments are calibrated /
validated every 3, 6 or 12 months in accordance with AASHTO. We provide
instrument & equipment support, offering on-site maintenance & repair where
none previously existed and act as agent to expedite the acquisition of
parts and support from the original equipment manufacturers (OEM).
· Viscosys is the only organization that offers a complete calibration /
validation service for a wide range of superpave equipment. We combine
multiple instrument types into one program, eliminating the need to have
engineers from several different organizations visit independently to
calibrate only one instrument. This reduces expenses & these savings reduce
the overall cost of superpave lab support.
· Contract or no contract, it’s your choice. Viscosys provides ad-hoc
calibration & maintenance services for customers that prefer not to have a
written contact of service.
· All equipment & materials used during on-site calibration or repair are
certified traceable to NIST (National Institute of Standards and
Technology).
· Calibration certificates and records issued at the time of the site visit
are also stored on our web server. Users are provided with a unique login to
access these records.
Pre-AMRL checklist.
As part of our calibration procedures, we check all instrument / tooling
tolerances as defined in the AMRL audit checklist for performance graded
binder (PGB) instruments. Results of this check are issued along with the
calibration documentation and stored on our web server.
Instrument / equipment type supported:
Bending Beam Rheometer T313-10
Independent Calibration / Validation of:
Displacement
Load cell
Temperature
Compliance
Step gauge and weights
Dynamic Shear Rheometer T315-10
Independent Calibration / Validation of:
Angular Displacement
Torque
Temperature
Alignment & measuring system tolerances
Direct Tension System T314-07
Independent Calibration / Validation of:
Displacement
Load cell
Temperature
Calibration spring
Rotational Viscometer T316-10
Independent Calibration / Validation of:
Torque
Rotational speed
Alignment & measuring system tolerances
Temperature
Rolling Thin Film Oven T240-09
Independent Calibration / Validation of:
Airflow
Temperature
Rotational speed
Pressurized Aging Vessel R28-09
Independent Calibration / Validation of:
Pressure
Temperature
Pressure Release rate
Vacuum oven pressure
Vacuum oven temperature